It is also possible that your web browser is not configured or not able to display style sheets. In this case, although the visual presentation will be degraded, the site should continue to be functional. We recommend using the latest version of Microsoft or Mozilla web browser to help minimise these problems.

Wiley InterScience

< Previous Abstract  |  Next Abstract >

Save Article to My Profile      Download Citation      Request Permissions

Abstract |  References  |  Full Text: HTML, PDF (Size: 170K)  | Related Articles | Citation Tracking

Left atrial mechanical functions in pre-eclampsia
Metin Ingec 1 , Mustafa Yilmaz 2 and Fuat Gundogdu 2
Departments of  1Obstetrics and Gynecology and  2Cardiology, University of Ataturk, Erzurum, Turkey
Correspondence to  Dr Metin Ingec, Solakzade Mah, Mevlana Cd, Sark 2000 Apt, A.Blok No 5 25070 Yenisehir, Erzurum, Turkey. Email: ingec@atauni.edu.tr
Copyright 2005 Blackwell Publishing Ltd
KEYWORDS
echocardiography • left atrial function • pre-eclampsia

Abstract

AbstractIntroductionMaterials and MethodsResultsDiscussionReferences

Aim: To assess the effect of short-term pressure overload on left atrial (LA) mechanical function in pre-eclampsia.

Methods: Twenty women with pre-eclampsia and 17 age-matched healthy pregnant women were included. LA volumes were measured echocardiographically at the time of mitral valve opening (Vmax), onset of atrial systole (p-wave at the electrocardiography = Vp) and mitral valve closure (Vmin) according to the biplane area-length method.

Results: The mean age, gestational age, weight and body surface area were similar in pre-eclampsia and controls. The ventricular septal and posterior wall thickness were greater in pre-eclampsia (P < 0.001). There were no significant differences in LA diameter, Vmax, Vmin, Vp, LA-passive emptying volume, LA-passive emptying fraction, LA-active emptying volume, LA-active emptying fraction, conduit volume, LA-total emptying volume and LA-total emptying fraction between the groups.

Conclusion: Left atrial mechanical function didn't change in pre-eclampsia. We conclude that short-lasting pressure overload is not capable of inducing changes in LA function.


Received: March 22 2005. Accepted: August 8 2005.

DIGITAL OBJECT IDENTIFIER (DOI)
10.1111/j.1447-0756.2005.00332.x About DOI