It is also possible that your web browser is not configured or not able to display style sheets. In this case, although the visual presentation will be degraded, the site should continue to be functional. We recommend using the latest version of Microsoft or Mozilla web browser to help minimise these problems.
Wiley InterScience | |||||||||
![]() Journal of MicroscopyVolume 212 Issue 2, Pages 144 - 151 Published Online: 12 Nov 2003 Journal compilation © 2010 Royal Microscopical Society
Abstract | References | Full Text: HTML, PDF (Size: 258K) | Related Articles | Citation Tracking Monitoring cell movements and volume changes with pulse-mode scanning ion conductance microscopy Copyright © 2003 The Royal Microscopical Society KEYWORDS Cell motility • cellular volume changes • difference imaging • line scans • perfusion chamber • scanning ion conductance microscopy • SICM Summary
Here we describe the use of pulse-mode scanning ion conductance microscopy (SICM) to observe volume changes and cell membrane movements during the locomotion of cultured cells in the range of minutes to several hours. The microscope is based on the pulse-mode SICM previously developed for stable imaging of single cells in culture. Our instrument uses current pulses to control the distance between cell surface and electrode tip as well as a back-step mode to prevent contact of tip and membrane during lateral movements of the probe. We performed repeated scans of cell surfaces using feedback-controlled piezoactors to position the electrode. Using patch-clamp-type electrode tips the height of cells could reproducibly be measured with a standard deviation of 50 nm. To quantify and separate changes in cell position and volume occurring between consecutive scans, a program was written to subtract images and calculate volume changes. Examples of repeated scans show that membrane movements in the range of 30 min to a few hours can be quantitatively monitored with a lateral resolution of 500 nm using difference images and that faster movements in the range of minutes can be recorded at defined cell sections using the line scan mode. Difference images indicate that volume changes can affect cell surfaces inhomogeneously, emphazising the role of the cytoskeleton in the stabilization of cell shape. Received 28 April 2003; accepted 3 July 2003 |