ADVERTISEMENT

If you are seeing this message, you may be experiencing temporary network problems. Please wait a few minutes and refresh the page. If the problem persists, you may wish to report it to your local Network Manager.

It is also possible that your web browser is not configured or not able to display style sheets. In this case, although the visual presentation will be degraded, the site should continue to be functional. We recommend using the latest version of Microsoft or Mozilla web browser to help minimise these problems.

Wiley InterScience

< Previous Abstract  |  Next Abstract >

Save Article to My Profile      Download Citation      Request Permissions

Abstract |  Full Text: HTML, PDF (Size: 579K)  | Related Articles | Citation Tracking

A microspectrophotometer for UV–visible absorption and fluorescence studies of protein crystals
Dominique Bourgeois Xavier Vernede Virgile Adam Emanuela Fioravanti Thomas Ursby
Correspondence to Dominique Bourgeois, e-mail: bourgeoi@lccp.ibs.fr
Copyright International Union of Crystallography, 2002
KEYWORDS
absorption and fluorescence microspectrophotometry • protein crystallography • macromolecular crystallography • fluorescein • temperature • pH.

ABSTRACT

Absorption microspectrophotometry has been shown to be of considerable help to probe crystalline proteins containing chromophores, metal centres, or coloured substrates/co-factors. Absorption spectra contribute to the proper interpretation of crystallographic structures, especially when transient intermediate states are studied. Here it is shown that fluorescence microspectrophotometry might also be used for such purposes if endogenous fluorophores are present in the macromolecule or when exogenous fluorophores are added and either bind to the protein or reside in the solvent channels. An off-line microspectrophotometer that is able to perform low-temperature absorption and fluorescence spectroscopy on crystals mounted in cryo-loops is described. One-shot steady-state emission spectra of outstanding quality were routinely collected from several samples. In some cases, crystals with optical densities that are too low or too high for absorption studies can still be tackled with fluorescence microspectrophotometry. The technique may be used for simple controls such as checking the presence, absence or redox state of a fluorescent substrate/co-factor. Potential applications in the field of kinetic crystallography are numerous. In addition, the possibility to probe key physico-chemical parameters of the crystal, such as temperature, pH or solvent viscosity, could trigger new studies in protein dynamics.


Received 12 October 2001, accepted 27 February 2002

DIGITAL OBJECT IDENTIFIER (DOI)
10.1107/S0021889802003837 About DOI

Related Articles

  • Find other articles like this in Wiley InterScience
  • Find articles in Wiley InterScience written by any of the authors

Wiley InterScience is a member of CrossRef.

Cross Ref Member