ADVERTISEMENT

If you are seeing this message, you may be experiencing temporary network problems. Please wait a few minutes and refresh the page. If the problem persists, you may wish to report it to your local Network Manager.

It is also possible that your web browser is not configured or not able to display style sheets. In this case, although the visual presentation will be degraded, the site should continue to be functional. We recommend using the latest version of Microsoft or Mozilla web browser to help minimise these problems.

Wiley InterScience

Acta Anaesthesiologica Scandinavica

Acta Anaesthesiologica Scandinavica

Volume 25 Issue 5, Pages 407 - 411

Published Online: 30 Dec 2008

Journal compilation © 2010 The Acta Anaesthesiologica Scandinavica Foundation



< Previous Abstract  |  Next Abstract >

Save Article to My Profile      Download Citation      Request Permissions

Abstract |  References  |  Full Text: PDF (Size: 784K)  | Related Articles | Citation Tracking

A New Tracheostomy Tube
III. Bronchofiberoptic Examination of the Trachea After Prolonged Intubation with the NL Tracheostomy Tube
N. Lomholt M.D.1,2, S. Borgeskov1 B. Kirkby1
 1Department of Pharmacology, University of Copenhagen and Department of Head and Neck Surgery, University Hospital, Copenhagen, Denmark
Correspondence to  2Dept. of Pharmacology University of Copenhagen 20, Juliane Maries Vej DK-2100 Copenhagen Ø Denmark
Copyright 1981 Acta Anaesthesiologica Scandinavica Fonden

ABSTRACT

Recent publications show that severe damage to the trachea is still a problem with high-volume, low-pressure cuffs. The NL tracheostomy tube was used in 85 patients for 3 days to 2 months (mean 16 days). This tube has a high-volume, low-pressure cuff with automatic regulation of the cuff pressure at 3kPa. The tube has a flexible tip. Fiberoptic examination at extubation showed minimal damage to the tracheal mucosa: 33 patients had normal mucosa and the rest had hyperaemia and/or fibrin formation. Four patients had ulcerations from suction catheters and four patients had small, superficial ulcerations produced by the tip of the lube. Of these last four patients, three had skin flaps that exerted pressure on the tube. Severe tracheal damage was prevented due to the combination of automatic regulation of cuff pressure and a flexible tip of the tube.


Received 7 January, 1981 accepted for publication 17 April 1981

DIGITAL OBJECT IDENTIFIER (DOI)
10.1111/j.1399-6576.1981.tb01675.x About DOI

Related Articles

  • Find other articles like this in Wiley InterScience
  • Find articles in Wiley InterScience written by any of the authors

Wiley InterScience is a member of CrossRef.

Cross Ref Member


ESA 2010 - Register Now
Sign Up Now
Sign Up Now
Submit your article today
Sign Up Now
Wiley Medical Twitter
Sign Up Now

Sign Up Now

Be the first to know about new research in your field

Sign up for FREE e-alerts from Wiley-Blackwell journals!

Sign Up Now